Products and Specifications
Tanks for Specialised Chemicals and Corrosives
T14 A24 24000 litre
 
Dimensions:
  Metric Imperial
Capacity 24000 LTR 6340 US GALLON
Maximum Gross Weight 34000 KG 74956 LBS
Tare 3600 KG 7936 LBS
Construction:   
Working Pressure 4.0 BAR 58 PSI
Test Pressure 6.0 BAR 87 PSI
Steam Working Pressure 4.0 BAR 58 PSI
Steam Test Pressure 6.0 BAR 87 PSI
Relief Valve 4.4 BAR 63 PSI
Ambient Temp. Range -40°C TO +65°C -40°F TO +149°F
Maximum Cargo Temp. 110°C 230°F
Shell Material Stainless steel, AISI 316 DIN 17441 1.4436
Thickness 4.8MM shell, 5.05MM ends, equivalent 6.35mm mild steel
Design Code ASME, section VIII, division 1
Approvals Lloyd's Register Construction Certificate, DOT UK IMO type 1, 
DOT US IM101, UIC, CTC, AAR, FRA, CSC, ISO, ADR, RID, BAM
Standard Fitting:
Manlid 500MM (20") diameter.
Calibration Volumetric stainless steel chart.
Airline 40 MM (1½") FV blacko ball valve, outlet 1½ " BSP, s/s screw cap.
Relief Valves 63mm (2½") BSP, operating pressure 4.4 bar.
Top Outlet 80 MM (3") FV butterfly valve, 80 MM (3") removable full length syphon tube, Outlet 3" BSTD, DIN 80, ASA 150 bolted blank flange.
Bottom Discharge Provision for 80mm (3") FV highlift foot valve and clamped 80mm (3") FV butterfly valve, outlet 3" BSP screw thread and cap.
Gaskets & Seals Parts in contact with cargo, PTFE/Teflon.
Steam Heating 7.5m²  (80'²) effective surface area external steam ducts ¾" BSP screw inlet/outlet and cap
Insulation 50mm (2") mineral wool (CFC free) segments, grp cladding, thermal value 47 Kcal/hr at 30°C.
Frame Beam frame with bolted side rails top and bottom.
Walkway Aluminium Q grating with access to top fittings, extending to manlid.
Compartment Top fittings protected in open stainless steel spillage box.
Document Holder Fitted rear end.

 

Actual measurements and specifications may vary and are subject to confirmation.  The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.

Download PDF