Products and Specifications
Tanks for Chemicals
T11 E24 Electric Heated 24000 Litre
 
Dimensions:
  Metric Imperial
Capacity 24000 LTR 6340 US GALLONS
Maximum Gross Weight 34000 KG 74956 LBS
Tare 3850 KG 8488 LBS
Construction:   
Working Pressure 4.0 BAR 58 PSI
Test Pressure 6.0 BAR 87 PSI
Steam Working Pressure 4.0 BAR 58 PSI
Steam Test Pressure 6.0 BAR 87 PSI
Relief Valve 4.4 BAR 63 PSI
 
Ambient Temp. Range -40°C to +65°C -40°F to +149°F
Maximum Cargo Temp 130°C 248°F
Shell Material Stainless steel, AISI 316(L) DIN 14404
Thickness 4.4 MM shell, 4.7mm ends, equivalent 6.35mm mild steel
Design Code ASME, section VIII, division 1
Approvals Bureau Veritas Construction Certificate, DOT UK IMO type 1, DOT US IM101, UIC, CTC, AAR, FRA, CSC, ISO, ADR, RID, IIR, BAM
Standard Fittings:
Manlid 500 MM (20") diameter.
Calibration Volumetric stainless steel chart.
Airline 40 MM (1½") blacko ball valve, outlet 1½" BS s/s screw cap, located in rear compartment.
Relief Valve 63 MM (2½") BSP, operating pressure 4.4 bar.
Top Outlet Blanked flange for optional fitting of 80mm (3") s/s butterfly valve, 80mm (3") removable syphon tube. Outlet 3" BSTD, DIN 80, ASA 150 bolted blank flange.
Bottom Discharge 80 MM (3") cleanflow foot valve and clamped 80mm (3") butterfly valve, Outlet 3" BSP screw thread and cap.
Remote Closure Bottom valve closure device fitted.
Gaskets & Seals Parts in contact with cargo, PTFE/Teflon.
Insulation 50 MM (2") isocyanurate (CFC free) rigid foam; white 2mm grp cladding; thermal value 37 Kcal/hr at 30°C.
Steam Heating 7.5m²  (80ft) effective surface area, external steam ducts, ¾" BSP screw inlet/outlet and cap.
Electric Heating Mannings thermal harness to external surface; effective area 12m² (130²). 11.5 KW Single voltage 440 3-phase AC. 20ft cable CEE17 plug.
Temperature Gauge 0-130°C fitted rear end.

 

Compartment Top fittings protected in open stainless steel spillage box.
Document Holder Fitted rear end.

 
Actual measurements and specifications may vary and are subject to confirmation.  The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.

Download PDF