Products and Specifications
Tanks for Specialised Chemicals and Corrosives
T14 H21 Hydrogen Peroxide 21000 litre
 
Dimensions:
  Metric Imperial
Capacity 21000 LTR 5548 US GALLONS
Maximum Gross Weight 34000 KG 74956 LBS
Tare 3470 KG 7650 LBS
Construction:   
Working Pressure 4.0 BAR 58 PSI
Test Pressure 6.0 BAR 87 PSI
Steam Working Pressure 4.0 BAR 58 PSI
Steam Test Pressure 6.0 BAR 87 PSI
Relief Valve 4.4 BAR 63 PSI
Rupture Disc 6.0 BAR 87 PSI
Ambient Temp.Rrange -40°C TO +65°C -40°F TO +149°F
Maximum Cargo Temp. 130°C 266°F
Shell Material Stainless steel, DIN 17441, no. 1.4436 equiv. BS 316 S33, AISI 316
Thickness 4.6MM shell, 5.05mm ends
Design Code ASME, section VIII, division 1
Approvals Lloyd's Register Construction Certificate, DOT UK IMO type 1, DOT US IM101, UIC, CTC, AAR, FRA, CSC, ISO, ADR, RID, BAM
Standard Fitting:
Manlid 500MM (20") diameter, 6 point fastening.
Calibration Volumetric stainless steel chart.
Air/Vapour Valve 40MM (1½") blacko ball valve, outlet 1½" BSTD, ASA 150, DIN40 bolted flange positioned at centre compartment.
Relief Valve 63MM (2½") BSP pressure operating.
Top Outlet 80MM (3") s/s butterfly valve, 80MM (3") removable full length syphon tube, outlet 3" BSTD, DN80, ASA 150 bolted outlet flange.
Top Fill Flange 80MM (3") adjacent to top valve, outlet 6 holes M12 PCD 168mm.
Bottom Discharge Welded blank flange for optional fitting of 80mm (3") cleanflow foot valve and clamped 80mm (3") butterfly valve.
Gaskets & Seals Parts in contact with cargo, PTFE/Teflon.
Temperature Gauge -10°C to 130°C, 14°F to 266°F, probe at 100cm depth, rear facing gauge.
Walkway Aluminium Q grating, full length and access to four corners and centre compartment.
Compartment Stainless steel protective spillage compartments to top fittings, aluminium lids.
Breather 50mm (2") combined sintered breather valve and pressure inlet valve, outlet 2" BSP screw thread.
Rupture Disc 260mm (10") Continental CDC-H (FS) rupture disc protected by s/s perforated cover guard.

 
Actual measurements and specifications may vary and are subject to confirmation.  The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.

Download PDF