Products and Specifications
Tanks for Specialised Chemicals and Corrosives
T20 A14 (D0T51) 14300 litre
 
Dimensions:
Capacity
14,300ltr
3778 US gallons
Maximum Gross Weight
34000kg
74956lb
Tare
4760kg
10493lb
Pressure:   
Working Pressure
6.9 bar
100 psi
Test Pressure
10.35 bar
150 psi
Relief Valve
6.9 bar
100 psi
Rupture Discs
7.58 bar
110 psi
Temperature:  
Ambient Temp. Range
-40°C to +65°C
-40°F to +149°F
Design Temperature
130°C
266°F
Maximum Cargo Temp
130°C
266°F
Shell Material Stainless steel, DIN 1.4401 (AISI 316)
Thickness 6.1 mm shell (0.24" equivalent to mild steel 8.0mm).
Design Code ASME, section VIII, division 1 with 'U' stamp.
Approvals Bureau Veritas Construction Certificate, DOT UK IMO type 1, DOT US 51, IMO, ISO, ADR, RID, CTC, AAR 600, TIR, UIC, CSC, T45, T38.
Standard Fittings:
Manlid 500mm (20") bolted manlid fitted with DIN100 loading aperture, blind flanged.
Calibration Volumetric Stainless steel chart, located inside fitting box.
Safety Relief 80mm (3") flanged super maxi highflow valve, at 6.89 bar, rupture disc at 7.5 bar, interspace pressure gauge.
Spare Flange 80mm (3") DIN 80 blind flange.
Fill/Discharge 80mm (3") top mounted ball valve, 3" removable full depth syphon pipe, Outlet 2" BSTD/Din 50 ASA 150 bolted flange.
Vapour Line 50mm (2") top mounted valve, outlet 2" BSTD/Din 50 bolted flange.
Air/Vapour Line 40mm (1.5") ball valve, outlet 1.5" BSTD/Din 40 blind flange.
Level Gauge DIN 80 levelling device, blind flanged. Located rear end.
Gaskets & Seals All parts in contact with the cargo PTFE/Teflon.
Compartments Spillage compartments fitted with hinged lockable s/s full protection lids.
Temperature Gauge -40°C to 130°C.
Insulation 100mm (4") mineral wool, approx 25kg/m3. cladding - 0.8mm white marine grade aluminium.
Steam Heating 10m² (107'²) effective heating area, 8 external steam ducts, ¾" BSP inlet/outlet and screw cap.
Walkway Full aluminium Q grating with two full length longitudinals and three transverse. Manlid covers act as walkway when open.
 

Download pdf

Actual measurements and specifications may vary and are subject to confirmation. The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.