Products and Specifications
Tanks for Specialised Chemicals and Corrosives
T14 A14 14300 litre
 
Dimensions:
  Metric Imperial
Capacity 14,300 LTR 3778 US GALLONS
Maximum Gross Weight 34000 KG 74956 LBS
Tare 3700 KG 8157 LBS
Construction:   
Working Pressure 4.0 BAR 58 PSI
Test Pressure 6.0 BAR 87 PSI
Steam Working Pressure 4.0 BAR 58 PSI
Steam Test Pressure 6.0 BAR 87 PSI
Relief Valve 4.4 BAR 63 PSI
Ambient Temp. Range -40°C TO +65°C -40°F TO +149°F
Maximum Cargo Temp 130°C 266°F
Standard fittings:
Shell Material Stainless steel DIN 1.4404 (AISI 316L), DIN 1.44041 (AISI 316)
Thickness 5.86mm shell, 6.5MM ends, equivalent 8.00mm mild steel.
Design Code ASME, section VIII, division 1
Approvals Bureau Veritas Construction Certificate, DOT UK IMO type 1, DOT US IM101, UIC, CTC, AAR, FRA, CSC, ISO, ADR, RID, BAM.
Manlid 500mm (20") diameter.
Calibration Volumetric stainless steel chart.
Airline 38mm (1½") blacko ball valve, outlet 1½" BSP, s/s screw cap, located in rear compartment.
Relief Valve 80mm (3") flanged fitted in series with bursting disc and pressure gauge.
Top Outlet 80mm (3") s/s butterfly valve, 80mm (3") removable full length syphon tube. Outlet 80mm (3") BSTD,DN80, ASA 150.
Vapour Return 80mm (3") bolted flange for optional fitting of vapour return.
Spare Flange 3" DIN 80, fitted in compartment with Vapour Return Flange
Bottom Discharge Welded 80mm (3") blank flange, insulated bottom outlet area.
Gaskets & Seals Parts in contact with cargo, PTFE/Teflon.
Steam Heating 7m²  (75ft²) effective surface area external steam ducts 
¾" BSP screw inlet/outlet and cap.
Insulation 50mm (2") Isocyanurate (CFC Free) rigid foam; white 2mm grp cladding; thermal value 37 Kcal/hr at 30 C.
Temperature Gauge -40°C - +150°C Fitted rear end.
Walkway 400mm wide non slip aluminium, access to all corners and valves.

 
Actual measurements and specifications may vary and are subject to confirmation.  The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.

Download PDF