Products and Specifications
Tanks for Specialised Chemicals and Corrosives
T20 A14 14000 litre
 
Dimensions:
  Metric Imperial
Capacity 14,300 LTR 3778 US GALLONS
Maximum Gross Weight 34000 KG 74956 LBS
Tare 4600 KG 10141 LBS
Construction:   
Working Pressure 6.79 BAR 98.5 PSI
Test Pressure 10.20 BAR 147.9 PSI
Steam Working Pressure 10.0 BAR 145 PSI
Steam Test Pressure 13.0 BAR 188 PSI
Relief Valve 6.6 BAR 95 PSI
 
Ambient Temp. Range -40°C to +65°C -40°F to +149°F
Maximum Cargo Temp 130°C 266°F
Shell Material Stainless steel, ASTM A240 din 17441 w 1.4401 (316l)
Thickness 6.7MM shell, 6.7mm ends, equivalent 8.0mm mild steel
Design Code ASME, section VIII, division 1
Approvals Bureau Veritas Construction Certificate, DOT UK IMO type 1, DOT US IM101, UIC, CTC, AAR, CSC/ACEP, ISO, RID,
Standard Fittings:
Manlid 500MM (20") diameter, 16 point bolted fixing
Calibration Volumetric stainless steel chart.
Airline 38MM (1½") ball valve, outlet 1½" BSTD/ DIN40 outlet, slotted holes, terminating in bolted blank plate.
Relief Valve 80mm(3") BSP, operating pressure 6.6 bar, in series with bursting disc and manometer.
Top Outlet 50MM (2") ball valve, 80mm (3") removable full length syphon tube, Outlet slotted 2" BSTD,DIN50,ASA 150 flange and bolted blank plate
Vapour Return 80MM (3") DIN 80 bolted flange for optional fitting of vapour return.
Spare Flange 3" DIN80, fitted in compartment with vapour return flange.
Bottom Discharge S/S blind tank pad totally concealed behind insulation and cladding for future fitting 80mm (3") highlift foot valve.
Gaskets & Seals Parts in contact with cargo, PTFE/Teflon.
Steam Heating 10m²  (107'²) effective surface area, seven external steam ducts ¾" BSP screw inlet/outlet and cap.
Insulation 100MM (5") rockwool; 0.8mm marine grade aluminium cladding, thermal value 18 Kcal/hr at 30°C.
Compartment Top fittings protected in stainless steel spillage box with hinged lids.
Document Holder Fitted rear end.
Thermometer -40°C to +150°C fitted rear end.
Walkway Aluminium Q grating with access to top fittings, extending to front end.

 
Actual measurements and specifications may vary and are subject to confirmation.  The authorised Dangerous Goods Advisor should confirm fitness for purpose of any tank and that the cargo is compatible and will not attack the tank vessel. Tank containers are supplied in accordance with a signed lease and GE SeaCo General Trading conditions.

Download PDF